Other presentations

iSWAB™-Animal DNA Collection Kit
SEE PRODUCT
iSWAB™-Animal DNA Collection Tube Rack
SEE PRODUCT

Benefits

benefits Icon

Non-Invasive collection methods including oral swabs, nasal swabs and hair pulls, are well-established methods to collect DNA from animals, but samples obtained from these procedures are tedious and require a time-consuming lab process. High bacterial content can potentially compromise the integrity of the sample, resulting in low sample output and suboptimal DNA quality for downstream applications. This can become a major issue when precious samples collected from a rare breed or exotic animal return from the lab with failed results and essentially no options for resampling. The iSWAB™ Proprietary technology ensures <3% bacterial genomic DNA contamination and it’s swab-free sample transport reduces sample processing time and cost without compromising sample integrity.

Product detail

Features

  • Simple, easy, and painless sample collection: Humane, non-invasive sample collection for multiple animal species in less than 2 minutes.
  • High quantity and quality nucleic acid recovery: Yields between 2-7µg of double stranded stranded, long fragment DNA ideal for genotyping, microarray, or NGS.
  • Low bacterial genomic DNA contamination: Proprietary buffer ensures <3% bacterial genomic DNA contamination.
  • Long-term ambient stability: Collected samples can be shipped and stored at room temperature, and are stable for 60 days (Real Time) with no loss of DNA quality. Ideal for lab or field-based collection.
  • Swab-free sample transport: Reduce sample processing time and cost without compromising sample integrity.
  • Traceable: LIMS-compatible unique barcodes are included on each iSWAB™ device for efficient traceability and storage.
  • Customizable: iSWAB kits and components can be customized to meet individual needs.
  • Scalable and easy to process: Manual and automation-friendly sample processing

iSWAB™-Animal DNA Collection Device Bag

Applications

Product Common Name: iSWAB™-ANML Bag

Product Full Name: iSWAB™-Animal DNA Collection Device Bag,

Part Number: ISAN-T

Units: 400uL x 500 Units

Includes:
500 iSWAB™-ANML Devices
Clear Bag
Labels

*The products shown contain the CE Mark and are approved for IVD use in countries recognizing this standard. In the USA, products are designated For Research Use Only and not for use in diagnostic procedures and will be labeled accordingly.

Animal sample collection, Speciation, Hereditary trait/disease ID, DNA banking, Parentage, Foresincs, Breed Identifications, Genotyping, Microarray, NGS.

Product Description

The iSWAB™-ANML device is a non-invasive collection system that maintains the integrity of the DNA at the point of collection for samples collected in the field. The swab used for collection is discarded after collection which has shown to significantly reduce processing time, effort, and costs. The iSWAB™-ANML is designed to be non-toxic and non-hazardous to enable safe and humane sample collection. The iSWAB device allows samples to be stored at room temperature for over 3 years and can yield 2-7 µg of double stranded stranded, long fragment DNA ideal for genotyping, microarray, or NGS.

Intended Use

iSWAB™-ANML Collection Device Bag is a DNA sample collection device for the collection, stabilization, concentration, storage, and transport of animal DNA samples. It is a non-invasive swab-based sampling applicator for the collection of DNA from various sample types including oral, nasal, and rectal. iSWAB™-ANML maintains the integrity of DNA at the point of collection for samples collected in the field. iSWAB-ANML collection kit for animals can capture samples producing high yields of double stranded, long fragmented DNA between 2-7μg (iSWAB™-ANML) with <3% bacterial contamination. Intended for speciation, hereditary traits, diseases, DNA banking, parentage, forensics, and breed identification. The iSWAB™-ANML is scalable and easily integrated in manual and automative sample processes.

Indication for Use (from IFU)

iSWAB™-ANML Collection Device Bag is a DNA sample collection device for the collection, stabilization, concentration, storage, and transport of animal DNA samples. It is a non-invasive swab-based sampling applicator for the collection of DNA from various sample types including oral, nasal, and rectal. iSWAB™-ANML maintains the integrity of DNA at the point of collection for samples collected in the field. iSWAB-ANML collection kit for animals can capture samples producing high yields of double stranded, long fragmented DNA between 2-7μg (iSWAB™-ANML) with <3% bacterial contamination. Ideal for genotyping, microarray, or NGS.

Storage and Stability

Pre-collection: 3 years from date of manufacture between 15-30° C.
Transport temperature, post-collection: 15-30° C.
Sample stability and storage, post-collection: 60 days real-time and 3 years accelerated time. If longer storage time is required, collected samples can be stored at -20 to -80° C.

Resources

Product
iSWAB™-ANML-250
Pre-Collection
Time Temp (C)
18 mo. DOM 15-30
Analyte
Typevvvvv
Genomic DNA
Post Collection
Time Temp (C)
60 days Real Time (3 yrs AT) 15-30
Cryo Storage
Temp (C)
-20- to -80
Attributes iSWAB™-ANML
Sample oral, nasal, and rectal
Use Animal DNA
# Swabs 1
Collection Volume 400 µL
Nucleic Acid Yield (μg) up to 7
Molecular Weight of DNA >23 kb
Bacterial DNA content <3%
Storage and Transport temperature RT
Shelf Life Stability 3 years
Post-Collection Stability 60 days real-time and 3 years accelerated time
Capability to concentrate sample Yes
Suitable for all population segments NA
Automation friendly Yes
Liquid Sample Yes
Barcoded Yes
Applications Animal sample collection, Speciation, Hereditary trait/disease ID, DNA banking, Parentage, Breed Identifications, Genotyping, Microarray, NGS
Compatible Assays Investigator Quantiplex Kit (Qiagen, Cat. # 387016), Promega PowerpPlex 16 HS System (Promega, Cat. # DC2101), EZ1 Advanced XL DNA Investigator Flip-Cap Card (Qiagen, Cat. # 9019933)

WARNING AND PRECAUTIONS

For external use and single use only. DO NOT drink, touch, or remove the buffer from the device. Do Not use if device is broken, leaking, or visibly damaged. These products should only be used in accordance with the instructions provided. Avoid eye contact with the liquid in the device. IF IN EYES: Rinse cautiously with water for several minutes. IF INGESTED: Call POISON CENTER. Rinse mouth. Not a Hazardous Combustion Product. Device cap can be a choking hazard. Do not ingest. Refer to SDS.